RADIK HYGIENE VK

Steel panel radiator for rooms with high demands on hygiene and cleanness, with flat front panel and right bottom connection

RADIK HYGIENE VK is a panel radiator in VENTIL KOMPAKT version which enables right bottom connection to the pressurized heating system.

It is suitable for installation and operation in rooms with high demands on hygiene and cleanness. All types are without convector fins; they have a flat front panel and the seam welds are covered with a special flat strip. The type 20S has got a bigger spacing between the panels (radiator depth B = 102 mm) as compared to the standard spacing of type 20 (B = 66 mm).

There are two upper and two lower hangers welded at the back side of the radiator. Radiators in length 1 800 mm and more have six hangers. An air-vent and blanking plugs are delivered as standard. We recommend using the drill-in brackets (type 18/120 – see the KORAMONT catalogue) which enable to mount the radiator in a distance of up to 65 mm from the wall.

Notice: If the requested distance between the radiator and the wall should be 65 ÷ 80 mm, the same type of brackets can be used on condition that the lower hangers are fixed with brackets (not with supporting pieces only). In such a case the additional brackets must be ordered extra.

Technical Data

Height (H)503, 603, 703 mm
Length (L)404, 504, 604, 704, 804, 904, 1004, 1104, 1204, 1404, 1604, 1804, 2004 mm
Depth (B)
- Type 10 HYGIENE VK49 mm
- Type 20S HYGIENE VK102 mm
- Type 30 HYGIENE VK157 mm
Connecting pitch50 mm
Connecting thread6 × G½ inside
Highest allowed working pressure10 bar
Highest allowed working temperature (°C)110 °C
Radiator connectionright bottom
Pressure Loss

In case of two-pipe heating system it is necessary to calculate the correct level of valve presetting and specify this in the project documentation to ensure a proper function of the heating system. This must be kept by the installer during installation of the heating system.

Heat output [W]


W
?
mm
mm
×

Temperatures

  • t1 - input water temperature
  • t2 - output water temperature
  • ti - desired room temperature

For the conversion of heat outputs change the default values.

Heat output calculated to ∆T= 50; (t1/t2/ti = for 75/65/20 °C)

Type 10 HYGIENE VK Type 20S HYGIENE VK Type 30 HYGIENE VK
Height [mm] Height [mm] Height [mm]
Length [mm] 503 603 703 503 603 703 503 603 703
404 174 200 225 326 380 433 466 539 607
504 217 250 280 407 474 540 581 672 758
604 260 300 336 488 568 647 696 805 908
704 303 349 391 569 662 755 812 938 1058
804 347 399 447 650 757 862 927 1072 1208
904 390 448 503 730 851 969 1042 1205 1359
1004 433 498 558 811 945 1076 1158 1338 1509
1104 476 548 614 892 1039 1183 1273 1472 1659
1204 519 597 669 973 1133 1291 1388 1605 1810
1404 605 696 781 1134 1321 1505 1619 1872 2110
1604 691 796 892 1296 1509 1719 1849 2138 2411
1804 778 895 1003 1458 1698 1934 2080 2405 2711
2004 864 994 1114 1619 1886 2148 2311 2671 3012