Ventilation and heat recovery units - technical parameters
Ventilation and heat recovery units - technical parameters
KORAVENT |
KORASMART |
KORASMART |
KORASMART TUBE |
KORASMART TUBE |
|
---|---|---|---|---|---|
Unit name | 100 | 1300 | 1400 | 2400 | 2400E |
Ordering code | VJ-VENT100 | VJ-SMART1300 | VJ-SMART1400 | VJ-SMART2400 | VJ-SMART2400E |
Noise absorption pursuant to EN 20140-10 / Dn,e,w | 50 dB | 52 dB | 35dB | ||
Air power output with a fan | G3: 30 –180 m3/h F5: 15 – 160 m3/h Activated carbon: 15 – 160 m3/h |
Level 1: 29 m3/h Level 2: 41 m3/h Level 3: 70 m3/h |
Level 1: 25 m3/h Level 4: 41 m3/h Level 10: 70 m3/h |
Level 1: 15 m3/h Level 2: 32 m3/h Level 3: 45 m3/h |
|
Operational noise LpA (measured according to DIN EN ISO 3741 or 3745, with A0 = 10 m2 ) at 8 dB room insulation | at 60 m3/h = 24 dB (A) | Level 1: 24 dB (A) Level 2: 30 dB (A) Level 3: 41 dB (A) |
Level 1: 21 dB (A) Level 4: 30 dB (A) Level 10: 41 dB (A) |
Level 1: 25 dB (A) Level 2: 38 dB (A) Level 3: 46 dB (A) |
|
Heat recovery efficiency | - | up to 66 % | up to 73 % | up to 90 % | |
Filter type | G3, F5, activated carbon | Supply air: F7 Exhaust air: G3 |
G3 | ||
Manual closing | yes | yes | yyes | ||
Motorised closing | - | - | |||
Remote control | - | - | yes | - | yes |
Thermostat control | - | - | yes | yes | |
Hygrostat control | - | - | yes | - | |
Timer control | yes | - | - | ||
Height | 467 mm | 467 mm | 279 mm | ||
Depth | 132 mm | 178 mm | 63 mm | ||
Width | 270 mm | 490 mm | 279 mm | ||
Assembly/installation loacation | On the wall | On the wall / in the wall | In the wall | ||
Electrical connection | 230 V | 230 V | 230 V | ||
Electrical power input | minimum fan power input = 2 W 60 m3 /h = 5 W max. fan power input = 30 W | Level 1: 10 W Level 2: 14 W Level 3: 29 W |
Level 1: 8 W Level 4: 14 W Level 10: 29 W |
Level 1: 2,1 W Level 2: 2,9 W Level 3: 4,3 W |
|
Surface colour | Plastic white, high-gloss | Plastic / white, matt | Plastic / white, gloss | ||
Additional information | Cable length: max. 4.5 m, white with Euro plug allowing permanent connection to power supply. | Cable length: max. 1.2 m, with Euro plug allowing permanent connection to power supply. | Fixed Connection to grid | ||
Operating range | 0 to +40 °C (on the inside) |
–15 to +40 °C | –15 to +40 °C | ||
Weight | 4,2 kg | 15 kg15,6 kg | 4.5 kg | ||
Warranty | 24 months | 24 months | 24 months |