RADIK CLEAN VK

Steel panel radiator for rooms with high demands on hygiene and cleanness with right bottom connection

RADIK CLEAN VK  is a steel panel radiator in the VENTIL KOMPAKT version which allows a bottom right connection to the heating system. It is designed for pressurised heating systems.

It has been modified for installation and operation in rooms with higher demands on hygiene and cleanness. All types are supplied without convector fins, top grills and side panels.

There are two upper and two lower hangers welded at the back side of the radiator. Radiators in length 1800 mm and more have six hangers. An air vent and blanking plugs are delivered as standard. We recommend using the drill-in brackets (type 18/120 – see the KORAMONT catalogue) which enable to mount the radiator in a distance of up to 65 mm from the wall.

Notice: If the requested distance between the radiator and the wall should be 65 ÷ 80 mm, the same type of brackets can be used on condition that the lower hangers are fixed with brackets (not with supporting pieces only). In such a case the additional brackets must be ordered extra.

Note: The RADIK CLEAN VK type 10 and RADIK VK type 10 radiators are identical.

Technical Data

Height (H)300, 400, 500, 600, 700, 900 mm
Length (L)400, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1400, 1600, 1800, 2000 mm
Depth (B)
- Type 10 CLEAN VK47 mm
- Type 20S CLEAN VK100 mm
- Type 30 CLEAN VK155 mm
Connecting pitch50 mm
Connecting thread6 × G½ inside
Highest allowed working pressure10 bar
Highest allowed working temperature (°C)110 °C
Radiator connectionright bottom
Pressure Loss

In case of two-pipe heating system it is necessary to calculate the correct level of valve presetting and specify this in the project documentation to ensure a proper function of the heating system. This must be kept by the installer during installation of the heating system.

Heat output [W]


W
?
mm
mm
×

Temperatures

  • t1 - input water temperature
  • t2 - output water temperature
  • ti - desired room temperature

For the conversion of heat outputs change the default values.

Heat output calculated to ∆T= 50; (t1/t2/ti = for 75/65/20 °C)

Type 10 CLEAN VK Type 20S CLEAN VK Type 30 CLEAN VK
Height [mm] Height [mm] Height [mm]
Length [mm] 300 400 500 600 700 900 500 600 700 900 500 600 700 900
400 206 242 278 350 359 417 474 585 512 593 673 834
500 165 212 257 302 347 438 449 522 593 732 640 741 841 1042
600 198 254 308 362 416 525 538 626 712 878 767 889 1009 1250
700 360 423 486 613 628 730 830 1024 895 1037 1177 1459
800 411 483 555 700 718 834 949 1170 1023 1186 1346 1667
900 463 544 625 788 807 939 1067 1317 1151 1334 1514 1876
1000 514 604 694 875 897 1043 1186 1463 1279 1482 1682 2084
1100 565 664 763 963 987 1147 1305 1609 1407 1630 1850 2292
1200 617 725 833 1050 1076 1252 1423 1756 1535 1778 2018 2501
1400 720 846 972 1225 1256 1460 1660 2048 1791 2075 2355 2918
1600 822 966 1110 1400 1435 1669 1898 2341 2046 2371 2691 3334
1800 925 1087 1249 1615 1877 2135 2302 2668 3028
2000 1028 1208 1388 1794 2086 2372 2558 2964 3364

Types of Connection